Telecom ESS GZ048100V1-C(4U) 48V 100Ah

WelsonPower Telecom Battery for Communication Base Station Backup Power solution GZ48100V1-C (4U) Up to 6000 Cycles, Built-in Smart BMS, Perfect for RV, Solar, Marine, Overland/Van,  Off Grid Applications.

  • LiFePO4 Safe Battery Chemistry with High energy density
  • Easy installation
  • Intelligent built-in BMS
  • Box-in Mounted& Parallel & Series Connection
  • Communication: CAN,RS485
  • Remote software program update, fault diagnosis
  • Visual interface, real-time monitoring of product status
  • >6,000 Cycles at 90% DOD
  • Low temp is available. Real time monitor battery.

Inquiry form

pls write down what your specific needing, thanks.

Category:

Description

Welsonpower Telecom Base Station Backup Standby Power Supply Battery Solution

Telecom Backup Battery Module 3U and 4U

Telecom ESS GZ048100V1-D(3U) 48V 100Ah Telecom ESS GZ048100V1-C(4U) 48V 100Ah

Telecom ESS GZ048100V1-D(3U) 48V 100Ah

  • 4.8kWh
  • 442*461*136mm
  • 40kg
  • 88.2LBS

GZ048100V1-C(4U) 48V 100Ah Telecom ESS

  • 4.8kWh
  • 445*450*175mm
  • 47.5kg
  • 104.7LBS

Technical Specifications Of GZ048100V1-C (4U)

Battery pack parameter

Item Project Parameter
1 Nominal Voltage 48.0Vdc
2 Nominal Capacity 100.0Ah
3 Voltage Range 42.0~54.75Vdc
4 Charging Voltage 54Vdc
5 Nominal Energy 4.8kWh
6 Available Energy 4.5kWh
7 Maximum Continuous Charge Current 50A
8 Maximum Pulse Charge Current 100A(10s)
9 Maximum Continuous Discharge Current 80A
10 Maximum Pulse Discharge Current 100A(10s)
11 Total discharge Energy or Service Life ≥14000kWh or 3600 cycles
12 Self-Discharge Rate ≤1%/week@35℃
13 Output Voltage Ripple ≤1%
14 Internal Resistance ≤30mΩ
15 Weight 47.5kg
16 Dimensions (width * depth * height) 445*450*175mm()
17 Operating Temperature Charge:0~60℃;Discharge: -20~60℃
18 Operating Relative Humidity 5%~95%,No condensation
19 Optimum Storage Temperature 10~35℃
20 Cooling Method Natural cooling
21 IP Code IP20
22 Communication Interface RS232/RS485
23 Support the number of parallel ≤16
24 Number of dry contacts 2

Cell parameters

Item Description Specification
Rated Capacity [email protected]
Nominal Voltage 3.20V
Charging Method CC/CV
Charging Voltage 3.65V
End-of-Charge Current CV Mode:0.05C(5.0A)
Discharge Ending Voltage 2.5V
Standard Charge Current 0.5C(50A)
Maximum Charge Current 1.0C(100A)
Standard Discharge Current 0.5C(50A)
Maximum Continuous Discharge Current 1.0C(100A)
Maximum Pulse Discharge Current 3.0C(30s)
Storage Voltage 3.20~3.30V
SOCRecommend SOC Window 10%~90%
Operating Temperature Range Charging Temperature:0~45℃
Discharging Temperature:-20~60℃
(1)Storage Temperature(1 year):-20~45℃
AC Impedance ≤0.5mΩ

(AC Impedance, 1000Hz)

Weight Approx.2300g
Dimension(L*W*T) 205.0±1.0*130.2±0.5*40.2±0.5mm

DATASHEET DOWNLOAD
PRODUCT USER MANUAL DOWNLOAD